Skip to content
Cart

Product Overview

The Pedestal Mount Eye Wash - Open Stainless Steel Bowl (Powder-Coated) provides emergency eye flushing capability as required by OSHA 29 CFR 1910.151(c). Designed to meet ANSI Z358.1 standards, this eyewash station delivers a controlled flow of tepid water to both eyes simultaneously for a minimum of 15 minutes.

Easy-to-activate with one hand, enabling injured workers to begin flushing immediately. Highly visible signage and bowl design guide users during emergencies when vision may be impaired.

Technical Specifications

Pedestal Mount Eye Wash - Open Stainless Steel Bowl (Powder-Coated) — Plumbed Eyewash Station

Product Name Pedestal Mount Eye Wash - Open Stainless Steel Bowl (Powder-Coated)
SKU AL85GSPJ
Type Emergency Eyewash Station
Compliance ANSI Z358.1, OSHA 1910.151
Sold By AbsorbentsOnline.com

Compare Eyewash & Shower Stations

Compare models within your product category to find the right fit for your facility

Plumbed Eyewash Stations — Mounting Options

Compare wall mount, pedestal mount, in-counter, and handheld eyewash stations
Feature Wall Mount Pedestal MountThis Type In-Counter Handheld
Installation Mounts directly to wall Free-standing floor pedestal Recessed into countertop Wall-mounted with handheld hose
Plumbing In-wall supply Floor supply (bottom) or top inlet Under-counter supply In-line water supply
Bowl Options Open stainless steel Open or closed; ABS or stainless Open stainless steel N/A — handheld nozzle(s)
Pipe Options N/A (wall bracket) Galvanized or stainless steel N/A (counter-recessed) N/A (hose connection)
Freeze Protection? ✗ Indoor only ✓ Available (120V/240V) ✗ Indoor only ✗ Indoor only
Best For Limited floor space, permanent install Open areas, versatile placement Labs, pharmacies, clean rooms Targeted flushing, body drench
Price Range From $865 $855.97 – $3,686.97 $1,290.25 $563 – $740.97

Pedestal Eyewash — Bowl & Pipe Options

Compare bowl and pipe material options for pedestal eyewash stations
Option Open Bowl + Galvanized Open Bowl + Stainless Closed Bowl + Galvanized Closed Bowl + Stainless
Bowl Type Open — ABS or stainless Open — ABS or stainless Closed ABS (dust cover) Closed ABS (dust cover)
Pipe Material Galvanized steel Stainless steel Galvanized steel Stainless steel
Corrosion Resistance Standard High Standard High
Contamination Protection Exposed — quick access Exposed — quick access Covered — prevents debris Covered — prevents debris
Best For Indoor, standard environments Corrosive or cleanroom settings Dusty or outdoor-adjacent areas Harsh/chemical environments

Expert Insights

ANSI Z358.1 requires eyewash stations within 10 seconds walking distance (approximately 55 feet) from any hazard. Tepid water (60-100°F) must flow for a minimum of 15 minutes. Weekly activation testing is mandatory — document each test with date and inspector initials.

Gravity-fed units require particular attention: replace water per manufacturer schedule (typically weekly to monthly depending on preservative used). For plumbed units, flush weekly for at least 3 minutes to prevent bacterial growth in stagnant water lines. Position stations on the same level as the hazard with no obstructions in the path.
Travis Zdrazil PCI Products — 40 Years in Industrial Spill Containment & Safety

Frequently Asked Questions

Pedestal Mount Eye Wash - Open Stainless Steel Bowl (Powder-Coated)

How often should I test the eyewash station?

ANSI Z358.1 requires weekly activation testing to flush stagnant water from supply lines and verify proper operation. Document each test with date and inspector name. Annual comprehensive inspections should verify flow rate, pattern, and water temperature.

How far should the eyewash be from the hazard?

ANSI Z358.1 requires the eyewash to be within 10 seconds travel time (approximately 55 feet) from any hazard. The path must be on the same level, free of obstructions, and well-lit. For strong acids and caustics, the distance should be even shorter.

What water temperature is required?

ANSI Z358.1 requires tepid water between 60°F and 100°F (16°C to 38°C). Cold water causes involuntary eye closure and hypothermia during the required 15-minute flush. Tempering valves are recommended for both hot and cold climates.

What is the difference between open and closed bowl eyewash stations?

Open bowl stations (stainless steel or ABS) allow instant access — just push the activation handle. Closed bowl (ABS) stations have a dust cover that flips open on activation, keeping the nozzles clean in dusty or outdoor-adjacent environments. Both types meet ANSI Z358.1 requirements.

When should I choose freeze-protected eyewash?

Choose freeze-protected pedestal-mount models when the station is installed outdoors or in unheated spaces where temperatures drop below 32°F (0°C). These units include electric heat tracing on the supply pipe and valve to prevent water from freezing. Available in 120V and 240V configurations.

Why Customers Choose AbsorbentsOnline

Facilities, field crews and government buyers have ordered from us since 1985.

Cross-Reference Guide

This product is compatible with applications using the following part numbers and specifications:

  • AL85GSPJ
  • Pedestal Mount Eye Wash - Open Stainless Steel Bowl (Powder-Coated)

Pedestal Mount Eye Wash - Open Stainless Steel Bowl (Powder-Coated). Professional-grade industrial safety product. AbsorbentsOnline SKU: AL85GSPJ. Contact us for cross-reference assistance with competitor part numbers.